⚡ Quick Answer: The Whirlpool dryer error F3E2 signals a malfunction with the moisture sensor, which can lead to inconsistent drying performance. This error typically... ✅ DIY Fixable
What Does Error F3E2 Mean?
The Whirlpool dryer error F3E2 signals a malfunction with the moisture sensor, which can lead to inconsistent drying performance. This error typically occurs when the sensor fails to detect moisture across five consecutive loads, resulting in either damp clothes or over-drying. Causes may include poor contact due to an unlevel dryer, small load sizes not triggering the sensor, or potential wiring issues.
Common Symptoms:
- Error F3E2 displayed on control panel
- Dryer stops or won’t complete cycles
- Automatic moisture sensing not working (clothes remain damp or over-dry)
Possible Causes
- Moisture sensor cannot register moisture levels (high)
- Dryer not level causing poor sensor contact (medium)
- Small or single-item loads failing to contact moisture sensors (medium)
- Loose wiring or defective moisture sensor component (medium)
How to Fix Error F3E2
DIY Fix Basic Troubleshooting and Reset
- Press the ‘Power’ button to clear the error and restart the dryer.
- Ensure the dryer is level using a carpenter’s level; adjust feet if needed.
- Try drying larger loads or multiple items rather than single small items.
- Perform a power cycle by turning off the circuit breaker for 1 minute, then restore power and start a cycle.
Technician Only Inspect and Repair Moisture Sensor and Wiring
- Disconnect power to the dryer.
- Access the moisture sensor inside the drum (usually metal strips near lint screen).
- Test moisture sensor continuity with a multimeter.
- Inspect and secure wiring connections between sensor and control board.
- Replace moisture sensor or harness if defective.
Parts needed: moisture sensor assembly, wire harness/connectors
- If basic user troubleshooting does not clear the error repeatedly
- If multimeter testing shows sensor or wiring faults
- If internal component replacement is needed and you are not experienced with dryer disassembly
Technical Specifications
| wattage | 5000W |
|---|---|
| component | Temperature Sensor |
| resistance | 10-30 ohms |
| part_number | WPW10150130 |
| voltage_rating | 240V AC |
Common Questions
What does F3E2 error mean on whirlpool dryer?
The F3E2 error indicates a malfunctioning moisture sensor, causing drying issues like damp or over-dried clothes.
Can I fix whirlpool dryer F3E2 error myself?
Yes, you can try basic troubleshooting like leveling the dryer or drying larger loads to resolve the issue.
How much does it cost to fix F3E2 error?
Repair costs for the F3E2 error typically range from $40 to $150 for parts, depending on the issue.
When should I call a technician for F3E2?
Call a technician if basic troubleshooting fails, multimeter testing shows faults, or if you need help with component replacement.