⚡ Quick Answer: The Whirlpool dryer error F13 signifies a temperature sensing issue, often linked to the temperature sensor (NTC) malfunction. This error may cause th... ✅ DIY Fixable

What Does Error F13 Mean?

The Whirlpool dryer error F13 signifies a temperature sensing issue, often linked to the temperature sensor (NTC) malfunction. This error may cause the drying cycle to fail to start, stop abruptly, or produce inadequate heat. It typically appears during the drying cycle, especially in washer-dryer combos, indicating potential airflow restrictions or faults in the heating circuit.

Common Symptoms:

  • Drying cycle fails to start or stops quickly during drying.
  • No or poor heat detected while attempting to dry.
  • Error appears specifically when entering or during drying cycle.

Possible Causes

  • Temperature sensor (NTC) malfunction (medium)
  • Restricted airflow / blocked duct or lint accumulation (medium)
  • Failure in heating circuit or dryer fan (medium)

How to Fix Error F13

DIY Fix Check venting and airflow

  1. Power off and unplug the dryer.
  2. Clean the lint trap.
  3. Inspect and remove lint or blockages from the vent hose and external exhaust.
  4. Ensure that the ductwork is not crushed or kinked.

DIY Fix Basic reset and initial check

  1. Unplug the dryer for 2–5 minutes.
  2. Plug back in and attempt a new drying cycle.
  3. Note whether the F13 code reappears.

Technician Only Test and replace dryer temperature sensor (NTC)

  1. Unplug the appliance and access the temperature sensor location (heater housing or exhaust duct).
  2. Measure resistance of the NTC sensor at room temperature and compare to spec.
  3. Replace the sensor if readings are outside tolerance or if open/shorted.
  4. Reassemble and test drying functionality.

Parts needed: Dryer NTC temperature sensor, Basic hand tools

Technician Only Inspect heating circuit, blower/fan, and wiring

  1. Disconnect power and open dryer access panels.
  2. Visually inspect wiring to heater, fan, and sensor for damage or loose connectors.
  3. Test heating element, blower motor, and fan for continuity and proper function.
  4. Replace any failed components and reassemble.

Parts needed: Heating element, Blower fan or motor, Wiring harness or connectors

🛑 When to Call a Pro:
  • If error persists after airflow cleaning and basic resets.
  • If measurements of sensor or heating circuit components are inconclusive or beyond user ability.
  • If access to internal components is not feasible or safe for the user.

Next step

Choose the next step for F13

Confirm the diagnosis before ordering. An error code can identify the system involved, but it does not prove that a specific part has failed.

Other parts options

Check related components first; use model search as a fallback.

Possible related component

Heating Element

Heats the water or air inside the appliance to the required temperature.

$40 - $95 · Medium · 30-45 mins

Check fit & price
Possible related component

Wiring Harness

Connects controls, sensors, motors, and other electrical components inside the appliance.

$20 - $120 · Medium · 30-90 mins

Check fit & price
Model number required

Model-compatible Dryer parts

Enter the complete model number to browse compatible replacement parts. This is a model-based parts search, not a diagnosis that a specific component failed.

Find a part that fits my model

Affiliate disclosure: As an Amazon Associate I earn from qualifying purchases. We may earn a commission from other qualifying purchases or service requests made through links on this page, at no additional cost to you. Recommendations are based on repair relevance, not commission rate.

Optional routine care

Maintenance supplies

These products support cleaning or routine upkeep. They are separate from the possible repair components above and are not claimed to fix this error code or symptom.

Maintenance supply

Dryer Vent Cleaning Kit

Helps remove routine lint buildup from an accessible dryer vent path. It does not diagnose or repair an E-code or failed component.

View maintenance supply
Maintenance supply

Lint Trap Cleaning Brush

A narrow brush for routine cleaning around an accessible lint screen and housing.

View maintenance supply
Maintenance supply

Dryer Vent Hose Kit

A replacement exhaust duct option for visibly crushed or damaged external venting. Check diameter, length, local code, and installation clearance.

View maintenance supply

Affiliate disclosure: As an Amazon Associate I earn from qualifying purchases. Recommendations are based on routine-care relevance, not commission rate.

Technical Specifications

note The previous model-independent part specification was removed. Verify the full model number and diagnosis in the manufacturer's official parts catalog before ordering.
part_number None

Common Questions

What does F13 error mean on whirlpool dryer?

F13 indicates a temperature sensing fault, leading to drying cycle failures and inadequate heat.

Can I fix whirlpool dryer F13 error myself?

Yes, check the venting for blockages and perform a basic reset by unplugging the dryer.

How much does it cost to fix F13 error?

Estimated repair costs range from $30 to $100 depending on parts needed.

When should I call a technician for F13?

Call a technician if the error persists after cleaning or if internal component access is unsafe.

Data last verified: 2026-07-31

User Comments (0)

Share your experience or solution below.

Be the first to comment!

Call Local Repair Provider +1 (888) 217-6318