Maytag Dryer Error L2
⚡ Quick Answer: The Maytag dryer L2 error indicates a low or insufficient line voltage supply, preventing the heating element from functioning properly. This often re... ✅ DIY Fixable
What Does Error L2 Mean?
The Maytag dryer L2 error indicates a low or insufficient line voltage supply, preventing the heating element from functioning properly. This often results in the dryer running without producing heat. Common causes include inadequate voltage reaching the unit or loose connections at the terminal block or power cord. If the error persists despite checking the power supply, it may indicate a fault in the control board.
Common Symptoms:
- Dryer runs but does not heat (heater circuit unable to energize) — as reported by multiple sources.
- Error L2 code displayed on control panel.
- Intermittent appearance of code even when apparent voltage at plug seems normal.
Possible Causes
- Insufficient or imbalanced line voltage supply (one leg of 240V missing or low) (high)
- Loose or burned connection at terminal block or power cord (medium)
How to Fix Error L2
DIY Fix Check Home Power Supply and Reset Breaker
- Ensure the dryer is unplugged before inspecting power.
- Check that both poles of the double‑pole circuit breaker feeding the dryer are not tripped; reset them if needed.
- Verify the dryer is plugged into a proper 240V outlet.
Technician Only Inspect and Test Voltage at Terminal Block and Connections
- Disconnect power and remove access panels to inspect the terminal block for burns or looseness.
- Confirm with a multimeter that ~240V is present between the two hot legs at the dryer's terminal block under load.
- Tighten or replace power cord and terminal block components if damaged.
Parts needed: Power cord, Terminal block
- If voltage tests show proper 240V but the L2 error persists — control board or diagnostic circuitry may be faulty.
- If electrical wiring in home is suspect or unsafe to test.
Technical Specifications
| wattage | 5400W |
|---|---|
| component | Heating Element |
| resistance | 10-30 ohms |
| part_number | WP3392519 |
| voltage_rating | 240V AC |
Common Questions
What does L2 error mean on maytag dryer?
L2 error on a Maytag dryer means low line voltage, preventing the heater from working, causing the dryer to run without heat.
Can I fix maytag dryer L2 error myself?
Yes, you can check your home's power supply and reset breakers, ensuring the dryer is properly plugged into a 240V outlet.
How much does it cost to fix L2 error?
Repairing the L2 error typically costs between $30 and $80, depending on the parts needed.
When should I call a technician for L2?
Call a technician if voltage tests are normal but the L2 error persists, or if you're unsure about inspecting the electrical wiring.
Sources & References
Data last verified: 2026-02-06
User Comments (0)
Share your experience or solution below.
Please login to post a comment.
Be the first to comment!