Maytag Dryer Error F6E2

⚡ Quick Answer: The Maytag dryer error code F6E2 signifies a communication failure between the control board and the user interface, leading to unresponsive buttons o... ✅ DIY Fixable

What Does Error F6E2 Mean?

The Maytag dryer error code F6E2 signifies a communication failure between the control board and the user interface, leading to unresponsive buttons or erratic display behavior. This issue often prevents the dryer from starting or cycling correctly. Temporary power resets may clear the error, but the problem is likely to recur due to loose or damaged wiring harness connections or faulty control boards.

Common Symptoms:

  • Dryer displays F6E2 at startup or during operation
  • Dryer may fail to start or cycle properly when the code is shown
  • Resetting power temporarily clears error but issue recurs

Possible Causes

  • Communication failure between control boards (control panel/user interface and main control board) (medium)
  • Loose or damaged wiring harness connections between control boards (medium)

How to Fix Error F6E2

DIY Fix Power Reset and Basic Check

  1. Disconnect dryer from power (unplug or turn off circuit breaker) for at least 5–10 minutes.
  2. Restore power and start a timed dry cycle.
  3. Observe for recurrence of the F6E2 code.

Technician Only Inspect and Secure Control Board Connections

  1. Unplug the dryer from power.
  2. Remove access panels to reach the main control board and user interface board.
  3. Disconnect and reconnect wiring harnesses between boards, checking for corrosion, bent pins, or damaged connectors.
  4. Replace or repair damaged wiring harnesses or connectors as needed.
  5. Reassemble and test dryer.
  6. If error persists, consider replacing the user interface/control panel or main control board based on diagnostic testing.

Parts needed: Control board (main), User interface/control panel, Wiring harness connectors

🛑 When to Call a Pro:
  • If you cannot safely access internal wiring or connectors
  • If error persists after reconnecting and checking wiring
  • If physical damage to control boards is suspected

Technical Specifications

wattage N/A
component Control Board
resistance N/A
part_number W10812395
voltage_rating 120V AC

Common Questions

What does F6E2 error mean on Maytag dryer?

F6E2 indicates a communication failure between the control board and user interface, causing unresponsive buttons.

Can I fix Maytag dryer F6E2 error myself?

Yes, you can try a power reset by disconnecting the dryer for 5–10 minutes and then observing if the error recurs.

How much does it cost to fix F6E2 error?

Repair costs range from $200 to $600+ depending on parts and labor required.

When should I call a technician for F6E2?

Call a technician if the error persists after checking connections or if you suspect physical damage to the control boards.