Maytag Dryer Error F4E4
⚡ Quick Answer: The Maytag dryer error F4E4 indicates an issue with insufficient incoming line voltage, affecting the heater circuit. This can prevent the dryer from ... ✅ DIY Fixable
What Does Error F4E4 Mean?
The Maytag dryer error F4E4 indicates an issue with insufficient incoming line voltage, affecting the heater circuit. This can prevent the dryer from heating or starting its heat cycle, while the drum may still spin normally. Often, this problem stems from a faulty power supply or loose connections.
Common Symptoms:
- Code displays on control panel at startup
- Dryer may not heat or may not start heat cycle
- Drum may spin normally while error appears
Possible Causes
- Insufficient incoming line voltage or power supply issue (high)
- Loose or faulty power cord/terminal block connection (medium)
How to Fix Error F4E4
DIY Fix Check household power and breakers
- Verify that the dryer is connected to a proper 240 V outlet
- Check that both breakers for the dryer circuit are not tripped
- Reset any tripped circuit breakers and try running the dryer again
DIY Fix Inspect power cord connection
- Unplug the dryer and pull it away from the wall
- Check that the power cord is properly installed at the dryer terminal block
- Ensure terminal screws are tight and free of corrosion
Technician Only Measure voltage under load and inspect wiring
- Use a multimeter to measure voltage between the two outer terminals at the dryer terminal block during a heating cycle to verify sustained 240 V
- Inspect wiring harness, power cord, receptacle and junction box for signs of wear, corrosion or loose connections
- Correct or replace wiring/components as needed
Parts needed: Multimeter, Replacement power cord or wiring connectors if needed
Technician Only Service or replace control board if voltage and connections are confirmed good
- If incoming voltage and connections are correct, test the main control board and replace if faulty
Parts needed: Control board assembly
- If proper 240 V does not reach the dryer even after checking breakers and connections
- If multimeter measurements show erratic voltage under load
- If internal wiring or components appear damaged or corroded
Technical Specifications
| wattage | N/A |
|---|---|
| component | Moisture Sensor |
| resistance | 10-30 ohms |
| part_number | WPW10149800 |
| voltage_rating | 120V AC |
Common Questions
What does F4E4 error mean on Maytag dryer?
F4E4 indicates low incoming voltage affecting the heater circuit, preventing proper drying.
Can I fix Maytag dryer F4E4 error myself?
Yes, check the power supply, circuit breakers, and inspect the power cord connection.
How much does it cost to fix F4E4 error?
Estimated repair costs range from $0 to $100 for DIY fixes.
When should I call a technician for F4E4?
Call a technician if voltage issues persist after troubleshooting or if internal components are damaged.
Sources & References
Data last verified: 2026-02-06
User Comments (0)
Share your experience or solution below.
Please login to post a comment.
Be the first to comment!