Maytag Dryer Error F4E4

⚡ Quick Answer: The Maytag dryer error F4E4 indicates an issue with insufficient incoming line voltage, affecting the heater circuit. This can prevent the dryer from ... ✅ DIY Fixable

What Does Error F4E4 Mean?

The Maytag dryer error F4E4 indicates an issue with insufficient incoming line voltage, affecting the heater circuit. This can prevent the dryer from heating or starting its heat cycle, while the drum may still spin normally. Often, this problem stems from a faulty power supply or loose connections.

Common Symptoms:

  • Code displays on control panel at startup
  • Dryer may not heat or may not start heat cycle
  • Drum may spin normally while error appears

Possible Causes

  • Insufficient incoming line voltage or power supply issue (high)
  • Loose or faulty power cord/terminal block connection (medium)

How to Fix Error F4E4

DIY Fix Check household power and breakers

  1. Verify that the dryer is connected to a proper 240 V outlet
  2. Check that both breakers for the dryer circuit are not tripped
  3. Reset any tripped circuit breakers and try running the dryer again

DIY Fix Inspect power cord connection

  1. Unplug the dryer and pull it away from the wall
  2. Check that the power cord is properly installed at the dryer terminal block
  3. Ensure terminal screws are tight and free of corrosion

Technician Only Measure voltage under load and inspect wiring

  1. Use a multimeter to measure voltage between the two outer terminals at the dryer terminal block during a heating cycle to verify sustained 240 V
  2. Inspect wiring harness, power cord, receptacle and junction box for signs of wear, corrosion or loose connections
  3. Correct or replace wiring/components as needed

Parts needed: Multimeter, Replacement power cord or wiring connectors if needed

Technician Only Service or replace control board if voltage and connections are confirmed good

  1. If incoming voltage and connections are correct, test the main control board and replace if faulty

Parts needed: Control board assembly

🛑 When to Call a Pro:
  • If proper 240 V does not reach the dryer even after checking breakers and connections
  • If multimeter measurements show erratic voltage under load
  • If internal wiring or components appear damaged or corroded

Technical Specifications

wattage N/A
component Moisture Sensor
resistance 10-30 ohms
part_number WPW10149800
voltage_rating 120V AC

Common Questions

What does F4E4 error mean on Maytag dryer?

F4E4 indicates low incoming voltage affecting the heater circuit, preventing proper drying.

Can I fix Maytag dryer F4E4 error myself?

Yes, check the power supply, circuit breakers, and inspect the power cord connection.

How much does it cost to fix F4E4 error?

Estimated repair costs range from $0 to $100 for DIY fixes.

When should I call a technician for F4E4?

Call a technician if voltage issues persist after troubleshooting or if internal components are damaged.