Maytag Dryer Error F22

⚡ Quick Answer: The Maytag dryer error code F22 signals a malfunction related to the outlet thermistor or control board. This issue commonly prevents the dryer from s... ✅ DIY Fixable

What Does Error F22 Mean?

The Maytag dryer error code F22 signals a malfunction related to the outlet thermistor or control board. This issue commonly prevents the dryer from starting or causes it to stop mid-cycle, particularly during heated cycles. The root cause often stems from a faulty outlet thermistor, which could be an open circuit or a failed sensor. Additionally, restricted airflow or damaged wiring may contribute to this error.

Common Symptoms:

  • Dryer displays F22 on control panel
  • Dryer may stop mid‑cycle, especially on heated cycles
  • Could prevent dryer from starting or heat cycle from running normally

Possible Causes

  • Faulty outlet thermistor (open circuit or failed sensor) (high)
  • Restricted airflow or clogged venting impacting thermistor readings (medium)
  • Loose or damaged wiring to the thermistor (medium)

How to Fix Error F22

DIY Fix Basic reset and airflow check

  1. Unplug the dryer or turn off the circuit breaker for a few minutes to reset the control.
  2. Clean the lint filter thoroughly.
  3. Inspect and clean the exhaust vent and outside vent to ensure unrestricted airflow.

Technician Only Test and replace the outlet thermistor

  1. Disconnect power to the dryer.
  2. Locate the outlet thermistor near the blower housing or exhaust duct.
  3. Test the thermistor resistance with a multimeter and compare to manufacturer specs.
  4. Replace the thermistor if readings are out of range.
  5. Inspect and secure wiring connections.

Parts needed: Outlet thermistor, Wiring harness/connectors

🛑 When to Call a Pro:
  • If the F22 error persists after cleaning airflow pathways and replacing the thermistor
  • If testing reveals other sensor faults or control communication issues
  • If user is not comfortable testing electrical components

Technical Specifications

wattage N/A
component Door Switch
resistance N/A
part_number WP3406107
voltage_rating 120V AC

Common Questions

What does F22 error mean on Maytag dryer?

F22 indicates a malfunction in the outlet thermistor or control board, often preventing the dryer from starting or stopping mid-cycle.

Can I fix Maytag dryer F22 error myself?

Yes, you can perform a basic reset, check airflow, and clean vents to troubleshoot the issue before considering replacement.

How much does it cost to fix F22 error?

Repair costs are generally low as the thermistor part is inexpensive, but labor costs may vary.

When should I call a technician for F22?

Call a technician if the error persists after cleaning, if other sensor faults are detected, or if you're uncomfortable testing electrical components.