⚡ Quick Answer: The Fisher & Paykel microwave error F10501-F20501 indicates an over-temperature condition within the microwave cavity, reaching approximately 698°F. ... ⚠️ Difficulty Varies
What Does Error F10501-F20501 Mean?
The Fisher & Paykel microwave error F10501-F20501 indicates an over-temperature condition within the microwave cavity, reaching approximately 698°F. This malfunction often causes the microwave to stop mid-cycle and may prevent it from heating further. Additionally, a malfunctioning temperature probe sensor could be the cause of this error. Users may notice unusual buzzing sounds and a very hot interior cavity during operation.
Common Symptoms:
- Microwave stops mid‑cycle
- Error code displayed on control panel
- Microwave may not heat further until serviced
- Possible very hot interior cavity
Possible Causes
- Cavity over‑temperature detected during cooking (high)
- Probe (temperature sensor) broken or malfunctioning (high)
How to Fix Error F10501-F20501
DIY Fix Basic checks before contacting service
- Stop using the microwave immediately when the error appears
- Allow the microwave to fully cool down before further inspection
- Verify that the microwave is not overloaded or containing materials not suitable for microwave cooking (e.g., metal)
- Check for obvious signs of damage or debris inside the cavity
Technician Only Diagnostic and repair steps
- Verify cavity temperature sensor (probe) integrity and replace if open/shorted
- Test associated temperature sensing circuits and wiring harness for continuity and proper connection
- Check components that may cause overheat events (e.g., magnetron, cooling fan performance, air circulation and ventilation)
- Replace faulty components as determined by multi‑meter diagnostics and service manual procedures
Parts needed: Temperature probe / sensor, Wiring harness, Control board if temperature sensor circuits affected
- If the error persists after cooling down
- If there are signs of burnt wiring, smoke, or unusual heat
- If the cavity temperature sensor or wiring is visibly damaged
Technical Specifications
| wattage | 1000W |
|---|---|
| component | Magnetron |
| resistance | 0.5-1.5 ohms |
| part_number | Fisher & Paykel 5304475039 |
| voltage_rating | 120V AC |
Common Questions
What does F10501-F20501 error mean on fisher & paykel microwave?
It indicates an over-temperature condition in the microwave cavity or a faulty temperature probe.
Can I fix fisher & paykel microwave F10501-F20501 error myself?
You can perform basic checks, such as allowing the microwave to cool and ensuring it’s not overloaded.
How much does it cost to fix F10501-F20501 error?
The estimated repair cost ranges from $150 to $450, depending on parts and service region.
When should I call a technician for F10501-F20501?
Call if the error persists after cooling, or if you notice burnt wiring or visible damage.
Sources & References
- Microwave Fault Codes - Fisher & Paykel (official)
- Microwave Fault Codes - Fisher & Paykel (AU) (official)
Data last verified: 2026-07-07