⚡ Quick Answer: The GE dryer E03 error code signifies a malfunction in the outlet thermistor, which is responsible for monitoring the dryer’s temperature. When this... ⚠️ Difficulty Varies

What Does Error E03 Mean?

The GE dryer E03 error code signifies a malfunction in the outlet thermistor, which is responsible for monitoring the dryer’s temperature. When this error occurs, the dryer may display E03 immediately upon startup or during operation, and it may stop heating or shut down mid-cycle due to the faulty sensor. Common causes include a defective thermistor, loose or damaged wiring, or an intermittent control board issue.

Common Symptoms:

  • Dryer displays E03 immediately on power up or during cycle
  • Dryer may stop heating or shut down mid-cycle due to temperature sensor fault

Possible Causes

  • Outlet thermistor defective (medium)
  • Loose or damaged wiring/connection at thermistor (medium)
  • Control board misinterpretation or intermittent fault (low)

How to Fix Error E03

DIY Fix Power cycle and check error persistence

  1. Unplug the dryer from the power source for 1–2 minutes.
  2. Reconnect power and attempt a normal cycle.
  3. Observe whether E03 returns immediately or only under load.

Technician Only Inspect and test outlet thermistor and wiring

  1. Disconnect power at the breaker.
  2. Access the dryer outlet thermistor (typically located near blower housing).
  3. Visually inspect wiring harness and connectors for damage or loose connections.
  4. Test thermistor resistance with multimeter comparing to manufacturer’s spec.
  5. Replace thermistor if out of spec.
  6. Reassemble and test dryer operation.

Parts needed: Outlet thermistor sensor, Wiring harness/connectors

🛑 When to Call a Pro:
  • If you are not comfortable accessing internal components due to mains voltage risks
  • If thermistor tests within spec but E03 persists — likely requiring professional diagnostic tools

Technical Specifications

wattage 5400W
component Heating Element
resistance 10-30 ohms
part_number WE11X10006
voltage_rating 240V AC

Common Questions

What does E03 error mean on GE dryer?

E03 indicates a malfunction in the outlet thermistor, affecting heat production.

Can I fix GE dryer E03 error myself?

Yes, you can power cycle the dryer and check if the error persists.

How much does it cost to fix E03 error?

Estimated repair cost is between $30–$120 for parts, plus labor.

When should I call a technician for E03?

Call a technician if you're uncomfortable with internal repairs or if the error persists after testing.