⚡ Quick Answer: The Mitsubishi Air Conditioner error code P8 signals a critical communication failure between the indoor and outdoor units, often caused by abnormal p... ✅ DIY Fixable
What Does Error P8 Mean?
The Mitsubishi Air Conditioner error code P8 signals a critical communication failure between the indoor and outdoor units, often caused by abnormal pipe temperature readings. This error typically leads to system shutdown, inefficient cooling or heating, and repeated operational interruptions. Common causes include thermistor or sensor issues, refrigerant circuit abnormalities, or faults within the outdoor unit itself. Immediate attention is advised to restore optimal performance.
Common Symptoms:
- System stops operation and displays P8
- Inefficient cooling/heating
- Possible unexpected shutdowns
Possible Causes
- Abnormal pipe temperature detected (thermistor/sensor issue) (high)
- Refrigerant circuit abnormality (blockage, low refrigerant causing temperature deviation) (medium)
- Outdoor unit related fault (sensor short/open, pressure/temperature protection) (medium)
How to Fix Error P8
DIY Fix Perform basic visual checks and restart
- Turn off the air conditioner using the remote or breaker
- Visually inspect outdoor unit area for debris or airflow obstruction
- Check for obvious loose wiring around accessible sensors
- Restore power and see if the error persists
Technician Only Diagnose and repair outdoor unit temperature sensor and refrigerant circuit
- Measure thermistor/pipe sensor resistance to verify within specification
- Confirm proper sensor mounting and wiring integrity
- Inspect refrigerant lines for blockages or leaks
- Check outdoor unit PC board for fault indications (LED codes)
- Replace faulty sensors or repair refrigerant circuit as needed
Parts needed: Pipe/line thermistor, Outdoor unit PC board (if faulty), Refrigerant (if leak detected)
- If error persists after basic checks and simple restart
- If you detect refrigerant leaks, abnormal noises, or repeated shutdowns
- When any internal wiring or component measurement is needed
Next step
Choose the next step for P8
Confirm the diagnosis before ordering. An error code can identify the system involved, but it does not prove that a specific part has failed.
Most relevant component to inspect
Thermistor
Measures precise temperature changes and sends resistance feedback to the control board.
- Typical part-only price
- $15 - $35
- DIY difficulty
- Easy
- Estimated time
- 15-30 mins
Where can I find the model number?
Check the rating label around the door, lid, frame, rear panel, or inside the appliance cabinet. Use the complete model number, including suffixes.
Verify the complete model and part number on the retailer's compatibility page before ordering.
Other parts options
Check related components first; use model search as a fallback.
Model-compatible Air Conditioner parts
Enter the complete model number to browse compatible replacement parts. This is a model-based parts search, not a diagnosis that a specific component failed.
Affiliate disclosure: As an Amazon Associate I earn from qualifying purchases. We may earn a commission from other qualifying purchases or service requests made through links on this page, at no additional cost to you. Recommendations are based on repair relevance, not commission rate.
Optional routine care
Maintenance supplies
These products support cleaning or routine upkeep. They are separate from the possible repair components above and are not claimed to fix this error code or symptom.
Air Conditioner Fin Cleaner
For routine cleaning of accessible coil fins when permitted by the manufacturer. Disconnect power and follow product and appliance instructions.
Model-Compatible Washable AC Filter
A reusable filter option only where the appliance supports one. Match the full model, dimensions, and filter specification.
Compatibility check required: use the complete appliance model and compare the existing filter, bag, or specification before ordering.
Affiliate disclosure: As an Amazon Associate I earn from qualifying purchases. Recommendations are based on routine-care relevance, not commission rate.
Technical Specifications
| wattage | N/A |
|---|---|
| component | Control Board |
| resistance | N/A |
| part_number | Mitsubishi 938B100A |
| voltage_rating | 230V AC |
Common Questions
What does P8 error mean on Mitsubishi Air Conditioner?
The P8 error indicates a communication failure between the indoor and outdoor units, often due to abnormal pipe temperature.
Can I fix Mitsubishi Air Conditioner P8 error myself?
Yes, you can perform basic visual checks and restart the unit by inspecting the outdoor area for debris and ensuring wiring is secure.
How much does it cost to fix P8 error?
The estimated repair cost for the P8 error ranges from ¥10,000 to ¥70,000+, depending on the parts needed and refrigerant work.
When should I call a technician for P8?
Call a technician if the error persists after basic checks, if you notice refrigerant leaks, or if the unit makes abnormal noises.
Data last verified: 2026-07-22