Kenmore Dryer Error F29
⚡ Quick Answer: The Kenmore Dryer F29 error code indicates a communication failure between the control board and the moisture sensor system. This often results in unr... ✅ DIY Fixable
What Does Error F29 Mean?
The Kenmore Dryer F29 error code indicates a communication failure between the control board and the moisture sensor system. This often results in unresponsive buttons, a blank display, and may prevent the dryer from starting or cause it to stop early in a cycle. Additionally, the automatic dryness sensing feature may become unreliable or disabled due to a malfunctioning moisture sensor or faulty wiring connections.
Common Symptoms:
- Dryer displays F29 and may not start a cycle.
- Dryer may stop early in cycle with F29 displayed.
- Automatic dryness sensing may be unreliable or disabled.
Possible Causes
- Moisture sensor malfunction or failure (high)
- Faulty wiring or poor connection to moisture sensor (medium)
How to Fix Error F29
DIY Fix Check moisture sensor connections and clean sensor bars
- Unplug the dryer from power.
- Locate the moisture sensor bars inside the drum.
- Inspect wiring connectors for secure fit and no corrosion.
- Wipe moisture sensor bars clean of any residue with a soft cloth.
- Restore power and test dryer operation.
Technician Only Test and replace moisture sensor assembly
- Disconnect power to the dryer.
- Access the moisture sensor assembly (often behind front panel near drum).
- Use a multimeter to test sensor resistance according to manufacturer specs.
- Replace the moisture sensor assembly if readings are outside acceptable range.
- Reassemble and test dryer cycles to verify resolution.
Parts needed: Moisture sensor assembly, Wiring harness/connectors if damaged
- If error persists after moisture sensor and wiring inspection.
- If internal access or diagnosis is beyond comfort/skill level.
Technical Specifications
| wattage | 500W |
|---|---|
| component | Control Board |
| resistance | 5-10 ohms |
| part_number | W10812394 |
| voltage_rating | 120V AC |
Common Questions
What does F29 error mean on Kenmore Dryer?
F29 indicates a communication failure between the control board and the moisture sensor, leading to unresponsive buttons.
Can I fix Kenmore Dryer F29 error myself?
Yes, you can check and clean the moisture sensor connections and inspect wiring for secure fits.
How much does it cost to fix F29 error?
The estimated cost for parts to fix the F29 error ranges from $30 to $150.
When should I call a technician for F29?
Call a technician if the error persists after checking the moisture sensor or if you're uncomfortable with the repair.
Data last verified: 2026-02-19
User Comments (0)
Share your experience or solution below.
Please login to post a comment.
Be the first to comment!