Sub Zero Wine Cooler Error 10-1-00
⚡ Quick Answer: The Sub Zero Wine Cooler error 10-1-00 indicates a failure in the Zone 1 cabinet thermistor, resulting in an open circuit. This can cause erratic temp... ⚠️ Difficulty Varies
What Does Error 10-1-00 Mean?
The Sub Zero Wine Cooler error 10-1-00 indicates a failure in the Zone 1 cabinet thermistor, resulting in an open circuit. This can cause erratic temperature readings and improper cooling in Zone 1, leading to potential spoilage of stored wine. If you see this error, the thermistor or its wiring may need inspection and repair.
Common Symptoms:
- Error code 10-1-00 displayed on the control panel.
- Temperature readings may be unavailable or incorrect for Zone 1.
- Possible improper cooling behavior in the affected zone.
Possible Causes
- Open circuit in Zone 1 cabinet thermistor or its wiring. (high)
How to Fix Error 10-1-00
DIY Fix Power cycle and check for temporary glitch
- Turn the home circuit breaker or unplug the wine cooler for at least 30 seconds.
- Restore power and observe if the error returns.
Technician Only Inspect and repair Zone 1 thermistor and wiring
- Access the internal thermistor sensor location for Zone 1 in the wine cooler.
- Use a multimeter to check thermistor resistance and continuity.
- Inspect wiring harness and connectors for damage, open circuits, or corrosion.
- Replace the thermistor if it reads open or outside expected resistance range.
- After repair, verify proper temperature readings and clear stored error codes with diagnostic tools.
Parts needed: Zone 1 thermistor sensor, Associated wiring harness/connectors
- If the error persists after power cycling.
- If the wiring or sensor location is inaccessible or you are not experienced with electrical diagnostics.
- If other error codes appear simultaneously indicating broader system faults.
Technical Specifications
| wattage | N/A |
|---|---|
| component | Temperature Sensor |
| resistance | 5-10 kOhms at 25°C |
| part_number | Sub Zero 7002100 |
| voltage_rating | 120V AC |
Common Questions
What does 10-1-00 error mean on Sub Zero Wine Cooler?
It indicates an open circuit in the Zone 1 cabinet thermistor, causing incorrect temperature readings.
Can I fix Sub Zero Wine Cooler 10-1-00 error myself?
Yes, try power cycling the unit. If the error persists, further inspection is needed.
How much does it cost to fix 10-1-00 error?
Repair costs range from ¥5,000 to ¥20,000 depending on parts and service.
When should I call a technician for 10-1-00?
Call if the error continues after power cycling or if you can't access the wiring.
Sources & References
Data last verified: 2026-04-23
User Comments (0)
Share your experience or solution below.
Please login to post a comment.
Be the first to comment!