Outdoor Faucet Vacuum Breaker Leaking? Identify It and Repair a Woodford Model 19
Quick Answer: Start with the hose off and look for the first wet point. A confirmed Woodford Model 19 that leaks through the top vacuum breaker while running may have debris or a damaged float assembly. Shut off and drain that branch, then service the top breaker using the matching instructions and RK-19VB kit if needed. Other faucet models and screw-on breakers need their own repair instructions.
On this page
Applicability and model notes
For outdoor hose bibbs and residential wall faucets with a visible vacuum breaker/backflow device. Irrigation assemblies and local code requirements may require a certified tester or plumber.
- Vacuum breakers are backflow protection devices. Leakage location and timing are clues, but they do not establish whether a device is failing or discharging as designed.
- Woodford lists different replacement components by faucet model. Match the exact faucet before choosing parts. An irrigation backflow assembly is not the same as a screw-on hose-bibb breaker.
Symptom checks
Water comes from holes on a small device near an outdoor faucet or hose connection.
First check: From a safe, dry position, note whether the water appears only while the faucet is on, during shutoff, or continues after the faucet is fully closed. Do not block the openings.
DIY Checks and Repairs
Locate the exact outlet and when it leaks
- From a dry position, observe whether water exits the hose-end fitting only while the faucet is on, continues after shutoff, or drips from the faucet body/stem. Do not remove or plug any backflow device. What to look for: A brief discharge at the air opening during pressure changes may differ from persistent leakage after shutoff. The location and duration help distinguish the hose-end vacuum breaker from the faucet valve or another assembly.
Identify the faucet and breaker before buying a part
- Without turning or dismantling anything, look for a brand/model marking on the faucet body or removable exterior label. Determine whether the device is a screw-on hose-end fitting or part of the faucet body. Use the manufacturer’s model finder and manual to confirm the proper part and whether it is user-replaceable. What to look for: A confirmed model and compatible kit support a parts decision. If the model is unknown, it is built in, or this is an irrigation backflow assembly, do not assume a generic replacement fits.
Clean or replace the top vacuum breaker on a confirmed Woodford Model 19
Tools needed: Small flat screwdriver for the plastic cap, Pliers, Woodford RK-19VB if the float assembly is damaged
- Remove the hose, close the upstream shutoff for this faucet, and open the outdoor handle until water stops. Use the diagram to identify the plastic cap and the breaker directly under it. What to look for: You can confirm that the branch is depressurized and that you are working on the top vacuum breaker. If water keeps running, leave the assembly closed.
- Carefully lift the plastic cap with a small screwdriver. Use pliers on the vacuum-breaker body as shown in Figure 4 and lift out the assembly. Check for loose grit and damaged float or sealing surfaces. Clear loose grit. If the float assembly is damaged, install the supplied Model 19 RK-19VB parts in the orientation shown in the kit instructions, then secure the cap. What to look for: The float assembly and cap are seated, with the vent unobstructed. A seized body or damaged faucet threads need a different repair. Leave the branch isolated if the assembly will not seat.
- Close the faucet, restore the upstream supply gradually, and dry the top cap. Run the faucet without a hose, watching the cap while water is flowing. Close the faucet and check whether water continues to come from the top cap, stem, or spout. What to look for: No sustained leak at the top cap during flow or after shutoff confirms the symptom has cleared under this test. If water still leaks, isolate the branch and check the seat, fit and location of the remaining leak before buying another part.
Stop and get qualified help when
Leave the breaker installed or isolate the branch if possible. A loose or leaking concealed connection can release water into the wall.
Keep the protection in place and use instructions or qualified service for that device. Do not force or drill unknown assemblies.
How to Verify the Repair
- Compare the same hose-off, steady-flow condition before and after repair. The top cap should stay dry during steady flow.
- With the faucet shut off and the hose still removed, confirm sustained drips do not come from the spout or stem. Those locations indicate a separate valve or packing issue.
- Where an irrigation assembly requires certified testing, have it tested before returning it to service.
Tools & replacement parts
Part
Woodford RK-19VB vacuum breaker float kit
Fits: Woodford Model 19 only, after confirming the stamped model; other faucet models require their own matched part
Check your model manual before ordering. Search results do not confirm compatibility.
As an Amazon Associate I earn from qualifying purchases.
Professional repairs
Assess a damaged faucet body or a concealed supply connection
Use this option if the body shifts, a wall joint leaks, or the isolation valve cannot shut off the branch. Share where water first appeared and during which test.
Test an irrigation backflow assembly when required
A certified tester can identify the assembly, determine its service requirements, and perform the applicable functional test.
Community discussions
These are individual reports, not verified repair instructions. Outcomes may not apply to your equipment.
An outdoor faucet spits water from holes around a knurled hose-end fitting, sometimes after shutoff.
Attempted: The owner asked whether the hose was wrong; commenters suggested the attached device was a backflow/vacuum breaker and that it could be failed or dirty.
No owner-confirmed repair or outcome is reported in the post.
When this may apply: Applies only as a clue for an apparent hose-end vacuum breaker on an outdoor faucet; identify whether it is an add-on, faucet-integrated device, or irrigation assembly before service.
Frequently asked questions
Can I cap the vacuum-breaker hole?
Will any vacuum-breaker repair kit fit my spigot?
Does the RK-19VB repair a steady drip from the main spout after shutoff?
References & sources
-
Outdoor spigot leaking questionr/Plumbing
Applies to: Single hose-bibb example; accessory and built-in vacuum breakers vary by faucet
Homeowner reports water spurting from small holes at the hose connection after shutoff; commenter identifies add-on vacuum breaker but the thread does not document a verified repair
-
Model 19 Troubleshooting and MaintenanceWoodford Manufacturing
Applies to: Woodford Model 19 only; not universal to other sillcocks or irrigation backflow assemblies
Model 19 instructions identify checking for fouling or replacing the model-specific vacuum-breaker float kit
-
Woodford Faucet FinderWoodford Manufacturing
Applies to: Woodford residential wall faucets only; identify exact model before ordering
Exact faucet model identification and compatible repair kits; Model 19 and other parts differ