LG Washer Dryer: water flooding during dry cycle

Professional Repair Guide

What is this symptom?

Experiencing water flooding during the dry cycle of your LG washer dryer combo? This issue may lead to soaking wet clothes and potential internal flooding. Typically, excess water could indicate a stuck inlet valve, a malfunctioning control board, or a clogged drain. Understanding these causes can help you address the problem effectively.

Urgency: High

Important Tips for LG Models

  • LG washer-dryer combos use a condensing system during drying that uses small amounts of water; some moisture or small water pools can be normal.

Possible Causes

Stuck or defective water inlet valve

How to Identify: Water continues flowing into drum during dry cycle or after wash completion; turning off water supply stops flooding; water still enters even when unit is off.

Part: Water inlet valve assembly (solenoid valve)

Control board energizing inlet valve at wrong times

How to Identify: Voltage present at the inlet valve solenoid when it should be off; unpredictable water filling behavior across cycles.

Part: Main control board

Poor drain clearance or clogged drain filter

How to Identify: Residual water remains because the drain pump cannot fully clear water; water backs up during dry cycle steam condensation.

Part: Drain pump filter / drain path

DIY Solutions

Inspect/clean drain pump filter and drain hose

Moderate 20–40 minutes
Tools Needed: screwdriver, bucket or towels
  1. Turn off and unplug the washer-dryer combo.
  2. Open the lower front access cover.
  3. Place a bucket/towels to catch residual water.
  4. Remove and clean the drain pump filter of debris.
  5. Straighten and inspect the drain hose; remove kinks or clogs.
  6. Reassemble and run a short cycle to test.
⚠️ Safety First: Ensure unit is powered off before accessing internal components.

Next step

Choose the next step for water flooding during dry cycle

Confirm the diagnosis before ordering. An error code can identify the system involved, but it does not prove that a specific part has failed.

Other parts options

Check related components first; use model search as a fallback.

Possible related component

Main Control Board

The central brain of the appliance that controls all components, cycles, and timings.

$120 - $280 · Medium · 20-40 mins

Check fit & price
Possible related component

Drain Pump

Pumps waste water out of the appliance during the drain cycle.

$35 - $80 · Easy · 15-30 mins

Check fit & price
Model number required

Model-compatible Washer Dryer parts

Enter the complete model number to browse compatible replacement parts. This is a model-based parts search, not a diagnosis that a specific component failed.

Find a part that fits my model

Affiliate disclosure: As an Amazon Associate I earn from qualifying purchases. We may earn a commission from other qualifying purchases or service requests made through links on this page, at no additional cost to you. Recommendations are based on repair relevance, not commission rate.

Optional routine care

Maintenance supplies

These products support cleaning or routine upkeep. They are separate from the possible repair components above and are not claimed to fix this error code or symptom.

Maintenance supply

Dryer Vent Cleaning Kit

Helps remove routine lint buildup from an accessible dryer vent path. It does not diagnose or repair an E-code or failed component.

View maintenance supply
Maintenance supply

Lint Trap Cleaning Brush

A narrow brush for routine cleaning around an accessible lint screen and housing.

View maintenance supply
Maintenance supply

Dryer Vent Hose Kit

A replacement exhaust duct option for visibly crushed or damaged external venting. Check diameter, length, local code, and installation clearance.

View maintenance supply

Affiliate disclosure: As an Amazon Associate I earn from qualifying purchases. Recommendations are based on routine-care relevance, not commission rate.

Professional Repairs

Replace water inlet valve assembly

Estimated Cost: $50 - $150

Replace/control board diagnosis and repair

Estimated Cost: $150 - $400

When to Call a Professional

If significant flooding persists after cleaning drains and verifying hoses.
If inlet valve replacement is beyond DIY capability.
If internal leaks or control board issues are suspected.

Preventive Maintenance

  • Clean drain pump filter: Water backing up and residual water accumulation during dry cycles
    Frequency: monthly
  • Inspect inlet hoses and valve for debris buildup: Valve sticking open and unintended water inflow
    Frequency: annually

Frequently Asked Questions

Why is my LG Washer Dryer Combo Water flooding during dry cycle?
Common causes include a stuck water inlet valve, a malfunctioning control board, or a clogged drain filter.
How do I fix LG Washer Dryer Combo Water flooding during dry cycle myself?
Turn off and unplug the unit, then clean the drain pump filter and drain hose.
How much does it cost to fix Water flooding during dry cycle?
Professional repairs range from $50 to $400 depending on the issue.
When should I call a technician for Water flooding during dry cycle?
If the problem persists after DIY attempts or if you suspect a control board issue.

References & Sources

Community Analytical Insights

Guidance from available sources; statistical claims are shown only for samples of at least 10 discussions

Common Issues Reported by Users

  • Faulty water inlet valve allowing water to flow during the dry cycle
  • Clogged drain hose causing water to back up into the washer dryer
  • Malfunctioning control board sending incorrect signals to the water inlet valve

User Suggested Solutions

  1. Inspect and replace the water inlet valve if defective. Disconnect power, locate the valve, and test it with a multimeter. If it fails, replace it with a new one.

  2. Check and clear the drain hose of any clogs. Remove the hose from the back of the unit and inspect it for blockages. Clean or replace as necessary.

  3. Test the control board for faults. If the control board is malfunctioning, it may need to be replaced. Consult the user manual for access instructions and consider professional help for replacement.

Limited-source guidance; percentages and success-rate claims are not shown
View Sources

Data compiled from real discussions on r/appliancerepair and r/Appliances:

  1. LG washer/dryer combo floods during the "dry" cycle

Community Discussions

floods during the dry cycle

Resetting the solenoid connections resolved the flooding issue.

Source: Reddit r/appliancerepair

User Comments (0)

Share your experience or solution below.

Be the first to comment!

Call Local Repair Provider +1 (888) 217-6318