Daikin Air Conditioner Error A6-00
⚡ Quick Answer: The Daikin air conditioner error A6-00 indicates a communication failure between the indoor and outdoor units, specifically linked to a malfunctioning... ✅ DIY Fixable
What Does Error A6-00 Mean?
The Daikin air conditioner error A6-00 indicates a communication failure between the indoor and outdoor units, specifically linked to a malfunctioning indoor fan motor. Symptoms include a non-operational fan, reduced airflow, and the A6 error code displayed on the remote. This issue can arise from fan motor failure, wiring problems, or obstructions affecting the fan blades.
Common Symptoms:
- Indoor unit fan does not run or stops
- Reduced or no airflow from the indoor unit
- Error code displayed on remote/controller indicating A6
Possible Causes
- Fan motor malfunction (medium)
- Fan motor wiring/connector issues (medium)
- Object obstructing fan blades (medium)
How to Fix Error A6-00
DIY Fix Basic user checks
- Turn off the air conditioner and isolate power (breaker off or unplug).
- Visually inspect the front air intake/grille for obvious obstructions.
- If safely accessible, check that the indoor fan area is clear of debris or blockage.
- Restore power and attempt a restart to see if the error clears.
Technician Only Professional diagnostic and repair
- Measure power and signals at the indoor fan motor to verify proper voltage and control signals.
- Inspect and test the fan motor wiring harness and connectors for continuity and secure connections.
- Check the fan motor for internal faults, bearing seizure, or overload condition.
- Replace the fan motor or associated wiring/connector parts if confirmed faulty.
- Inspect control board outputs to the fan motor and replace board if necessary.
Parts needed: fan motor assembly, wiring harness and connectors, possibly indoor unit control board
- If error persists after basic checks
- If unusual noises, burning smell, or repeated shutdowns occur
- If user is not comfortable accessing fan area
Technical Specifications
| wattage | N/A |
|---|---|
| component | Control Board |
| resistance | N/A |
| part_number | DAIKIN 4E188F |
| voltage_rating | 220V AC |
Common Questions
What does A6-00 error mean on daikin air conditioner?
A6-00 indicates a communication failure due to an indoor fan motor malfunction.
Can I fix daikin air conditioner A6-00 error myself?
Yes, you can perform basic checks like inspecting for obstructions and ensuring power is off.
How much does it cost to fix A6-00 error?
Repair costs range from $100 to $500+, depending on parts and service rates.
When should I call a technician for A6-00?
Call a technician if the error persists after checks or if you hear unusual noises or smell burning.
Data last verified: 2026-07-01
User Comments (0)
Share your experience or solution below.
Please login to post a comment.
Be the first to comment!