Daewoo Dehumidifier Error CL

⚡ Quick Answer: The Daewoo dehumidifier CL error code indicates a temperature-related shutdown condition due to low ambient temperature, which may prevent the unit fr... ✅ DIY Fixable

What Does Error CL Mean?

The Daewoo dehumidifier CL error code indicates a temperature-related shutdown condition due to low ambient temperature, which may prevent the unit from operating. When the CL error appears, it signifies that the condensate level sensor is triggered, often in environments below the manufacturer's specified temperature range of about 5°C. To resolve this, ensure the unit is placed in a warmer area and power cycle it after adjusting the room temperature.

Common Symptoms:

  • Unit stops operating or will not run when CL appears
  • May coincide with low room temperature outside operating range
  • No other typical fault symptoms like sensor or mechanical failure

Possible Causes

  • Low ambient temperature outside operating range (high)

How to Fix Error CL

DIY Fix Check and adjust room temperature

  1. Ensure the dehumidifier is operating in a room within the manufacturer’s specified temperature range. turn
  2. Move the unit to a warmer area or raise ambient temperature before restarting.
  3. Once temperature is appropriate, power cycle the dehumidifier (turn off then on).

Technician Only Verify temperature sensor and operation range

  1. Measure ambient temperature where the unit is placed.
  2. Confirm the CL display coincides with low temperature by observing operation at acceptable temperatures.
  3. If CL persists despite suitable environment, inspect the temperature sensor and related wiring for faults.
  4. Replace temperature sensor only if proven defective after testing with appropriate measurement tools.

Parts needed: Temperature sensor, Wiring harness

🛑 When to Call a Pro:
  • {'note': 'If CL does not clear even when ambient is within spec and simple user checks fail, contact service for sensor diagnosis and potential part replacement.', 'condition': 'Error persists in normal operating temperature'}

Technical Specifications

wattage 300W
component Condensate Level Sensor
resistance 5-15 ohms
part_number DAE-CL-SENSOR-001
voltage_rating 120V AC

Common Questions

What does CL error mean on daewoo dehumidifier?

The CL error indicates a temperature-related shutdown, usually due to low ambient temperature.

Can I fix daewoo dehumidifier CL error myself?

Yes, check the room temperature and ensure it's above 5°C, then power cycle the unit.

How much does it cost to fix CL error?

Repair costs range from $15 to $60 for parts, plus variable labor.

When should I call a technician for CL?

Contact a technician if the CL error persists in normal temperatures despite user checks.

Sources & References

Data last verified: 2026-07-07

User Comments (0)

Share your experience or solution below.

Be the first to comment!